
Add to Cart
Access Traffic Optical Bypass Switch Network TAP Multimode Optical Protection Link
1.Overviews
With the rapid development of the Internet, the threat of network information security is becoming more and more serious, so a variety of information security protection applications are used more and more widely. Whether it is traditional access control equipment (firewall) or a new type of more advanced protection means such as intrusion prevention system (IPS),Unified threat management platform (UTM), Anti-denial service attack system (Anti-DDoS), Anti-spam Gateway, Unified DPI Traffic Identification and Control System, and many security devices are deployed in series in the network key nodes, the implementation of the corresponding data security policy to identify and deal with legal / illegal traffic. At the same time, however, the computer network will generate a large network delay or even network disruption in the case of fail over, maintenance, upgrade, equipment replacement and so on in a highly reliable production network application environment, users cannot stand it.
2.Intelligent Bypass Swtich Application Solution
Link Series Device Protection
Figure 1: Policy Traffic Traction Protector Bypass Switch Data Flow
As shown in Figures 1, the NetTAP® "Policy Traffic Traction Protector" is deployed in series between network devices (routers, switches, etc.), and the data flow between network devices no longer leads directly to IPS / FW, NetTAP® "policy traction protector" to IPS / FW, when the IPS / FW due to overload, crash, software updates, policy updates and other conditions of failure, the "bypass switch" through intelligent heartbeat message detection Function of the timely discovery, and thus skip the faulty device, without interrupting the premise of the network, the rapid network equipment directly connected to protect the normal communication network; when the IPS / FW failure recovery, but also through intelligent heartbeat packets Detection of timely detection of the function, the original link to restore the security of enterprise network security checks.
NetTAP® "Bypass switch" has a powerful intelligent heartbeat message detection function, the user can customize the heartbeat interval and the maximum number of retries, through a custom heartbeat message on the IPS / FW for health testing, such as send the heartbeat check message to the upstream / downstream port of IPS / FW, and then receive from the upstream / downstream port of IPS / FW, and judge whether the IPS / FW is working normally by sending and receiving the heartbeat message.
3. Bypass Switch Bypass TAP Technical Characteristics
SpecFlow/FullLink Protection
The NetTAP® "INLINE Network Security Bypass Swtich based on Network TAP Strategic Traffic Protector" supports serial protection for complete link traffic and a serial protection mode for a specific traffic type. Users can choose the appropriate deployment mode according to the deployment requirements of different security devices.
FullLink protection mode. In this mode, the Policy Traffic Traction Protector forwards all traffic from the deployed link to the security device and performs real-time monitoring of the state of the security device. If the status of the security device is abnormal, the protector will automatically switch to the bypass state ensures network availability.
SepcFlow protection mode. In this mode, the Policy Traffic Traction Protector forwards some of the user-specified traffic types in the deployment link to the security device for processing. The remaining traffic is automatically bypassed without passing through the security device. While the protector on the state of the safety device to perform real-time monitoring, once the safety device status is abnormal, the protector will automatically switch to bypass state to ensure the availability of the network.
Speed BYPASS switch
The NetTAP® policy traffic traction protector has a very low switching latency to minimize the impact the user network has during the handover process. NetTAP® Policy Traction Protector the switchover duration is <50ms and the NetTAP® policy traffic traction protector has an optical port switching duration of <8ms. In the case of a security device failure, the NetTAP® policy traffic traction protector performs a failure state switch that the user has almost no effect on the network.
4. Bypass Switch Bypass TAP Technical Specifications
Product model | Specifications |
NT-FBYP-L1X-SR | 1U chassis, 1*10GE multimode optical protection link |
NT-FBYP-L1X-LR | 1U chassis, 1*10GE single-mode optical protection link |
NT-FBYP-L1G-SX | 1U chassis, 1*GE multi-mode optical protection link |
NT-FBYP-L1G-LX | 1U chassis, 1*GE single mode optical protection link |
NT-CBYP-L1G | 1U chassis, 1*GE electrical protection link |
NT-CBYP-L2G | 1U chassis, 2*GE electrical protection link |
NT-FBYP-L2G-SX5 | 1U chassis, 2*GE multi-mode optical protection link |
NT-FBYP-L2G-LX | 1U chassis, 2*GE single-mode optical protection link |
NT-FCBYP-L4XG-SR | 1U chassis, 2*GE electrical protection link, 1*GE multi-mode optical protection link, 1*10GE multimode optical protection link |
NT-FCBYP-L4XG-LR | 1U chassis, 2*GE electrical protection link, 1*GE single mode optical protection link, 1*10GE single mode optical protection link |
1*10GE Optical BYPASS link(NT-FBYP-L1X-SR)
Product Model | NT-FBYP-L1X-SR Optical Bypass Network TAP | |
Interface form | SFP + slot | 2 * SFP + interface, support 10 Gigabit optical / electrical modules |
10G optical Bypass link | 1 link, 2 * 10Gbase-SR multimode interface | |
Deploy mode | Number of link protection links | Maximum support for a 10GE BYPASS link |
Monitor | 1*10GE monitoring link (2 * SFP + slot), supported 10GBASE-LR/SR | |
Index parameter | Multi-mode insertion loss | 1.1dB to 1.6dB |
Multimode emission optical power | -7.3dB to 1dB | |
Multimode receive optical power | ≥-12dB | |
Multimode operating wavelength | 850nm | |
Multimode transmission distance | 300M | |
Single mode short insertion loss | 1.1dB to 1.6dB | |
Single mode short distance emission optical power | -6dB to 0.5dB | |
Single mode short distance receiving optical power | ≥-14dB | |
Single mode short working wavelength | 1310nm | |
Single mode short distance transmission distance | 10KM | |
Single mode mid - range insertion loss | 1.1dB to 1.6dB | |
Single mode mid - range emitting optical power | -1dB to 3dB | |
Single mode mid - range received optical power | ≥-18dB | |
Single mode midpoint working wavelength | 1550nm | |
Single mode distance transmission distance | 40KM | |
Single mode long distance insertion loss | 1.1dB to 1.6dB | |
Single mode long distance emission optical power | 0dB to 4dB | |
Single mode long distance receiving optical power | ≥-24dB | |
Single mode long distance working wavelength | 1550nm | |
Single mode long distance transmission distance | 80KM | |
Functional performance | Total number of interfaces | 4 |
Line speed processing capacity | 40Gbps | |
Cross - link protection based on IP / protocol / port quintuple specific traffic | Support | |
Based on the total flow of the series protection | Support | |
Multi - channel load balancing function | - | |
Custom heartbeat message function | Support | |
Ethernet encapsulation support | Support | |
BYPASS switching function | Support | |
Bypass switch without flash | Support | |
CONSOLE network management | Support | |
IP/WEB network management | Support | |
SNMP V1/V2C network management | Support | |
TELNET/SSH network management | Support | |
SYSLOG protocol | Support | |
User authentication function | Based on user name and password authentication | |
Electric | Rated supply voltage | AC-220V/DC-48V【Optional】 |
Rated power frequency | 50HZ | |
Rated input current | AC-3A / DC-10A | |
Rated Power | 45W | |
Environment | Working Temperature | 0-50℃ |
Storage temperature | -20-70℃ | |
Working humidity | 10%-95%,No condensation | |
User configuration | console configuration | RS232 interface,9600,8,N,1 |
Outside network management interface | 1*10/100/1000M Ethernet interface | |
Password authentication | Support | |
Dimension | Chassis dimension(U) | 1U 485mm*44.5mm*350mm |